For use in separation of ink mist used on dry particles of water based paint.




| Hydro Stop | |
| Paint mist arrestance approx. * | 98% |
| Filter class acc. to ISO 16890 | ISO Coarse 55% |
| * The degree of separation depends on type of paint, overspray or environmental conditions such as the temperature or pressure in the cabin. | |
| Technical data: | Hydro Stop | |
| Filter area | [m2] | 1 |
| Material thickness approx. | [mm] | 75 |
| Recommended nominal air flow | [m3/h/m2] | 2.700 |
| Air velocity | [m/s] | 0,75 |
| Initial pressure drop (measured at air velocity on a flat sheet 610 x 610 mm) | [Pa] | 7 |
Reach out to us from our contact form and we will get back to you shortly.